| Genset Rating | Prime Power |
| Brand | Greaves Power |
| Fuel Tank Capacity | 100 L |
| Phase | Three Phase |
| Power | 45A kVA |
| Battery Capacity | 88 AH |
| Compression Ratio | 17.5 |
| Dimension | 2350 x 950 x 1380 mm |
| Maximum Allowable Back Pressure | 6 kPa |
| Weight | 1400 kg |
| Displacement | 2.86 L |
| Class of Governing | Mechanical |
| Over Speed Trip | 1650 RPM |
| Bore and Stroke | 91X110 mm |
| Alternator Type | 4 Pole, Rotating field |
| Battery Capacity | 88 AH |
| Brand | Greaves Power |
| Compression Ratio | 17.5 |
| Dimension | 2350 x 950 x 1380 mm |
| Fuel Tank Capacity | 100 L |
| Maximum Allowable Back Pressure | 6 kPa |
| Weight | 1400 kg |
| Displacement | 2.86 L |
| Class of Governing | Mechanical |
| Over Speed Trip | 1650 RPM |
| Air Cleaner Type | Dry |
| Genset Rating | Prime Power |
| Engine Rating or Maximum Power at Rated RPM | 42.8 KW (58 BHP) |
| Bore and Stroke | 91X110 mm |
| Charging Alternator Voltage | 12 VDC |
| Current | 35 A (DC) |
| Starter Motor Rated Voltage | 12 VDC |
| Genset Model | GPWII- 45A |
| Battery Voltage | 12 VDC |
| Recommended Fuel | HSD |
| Oil Change Period | 500 hrs |
| Recommended Oil Grade | 15W40, Greaves Maxtherm, API CI4 |
| Oil Cooler | Water Cooled |
| Radiator System capacity | 15 L (including engine) |
| Water Pump Type | Engine Mounted |
| Alternator Voltage | 380-440 V |
| Alternator Frequency | 50 Hz |
| Alternator Current | 62.6 A (@ 0.8 PF) |
| Engine Model | G-40-II |
| Alternator Exciter Type | Brush-less (Permanent magnet optional) |
| Alternator Voltage Regulator | Solid State |
| Alternator Insulation | Class H |
| Alternator Temperature Rise | 125 Deg. C (Class H) |
| Alternator Coupling | Flexible disc close coupled |
| Alternator Voltage Regulation | 2 Phase sensing, +/-1% |
| One Step Load Acceptance | 100% of rating |
| Unbalance Load Capability | 25% of rated current |
| Engine Type | TCAC |
| No of Cylinders | 4 |
| Cylinder Arrangement | Inline |
| Genset Output ( KVA / KW) | 45 / 36 |
| Rated RPM | 1500 |
| Governor Type | G2 |
Power (kVA)500 kVAGenset BrandGreaves PowerModel NumberGPWII-500Phase3 PhaseFuel Consumption (at 100% Load)107.9 Ltr/hrF... Continue
Power (kVA)400 kVAGenset BrandGreaves PowerModel NumberGPWII-400Phase3 PhaseFuel Consumption (at 100% Load)88.8 ltr/hrFu... Continue
Power (kVA)40 kVAGenset BrandGreaves PowerModel NumberGPWII-40APhase3 PhaseFuel Consumption (at 100% Load)9 Ltr/hrFuel T... Continue
Power (kVA)180 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-180Phase3 PhaseFu... Continue
Power (kVA)25 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-25EPhase3 PhaseFuel Consumption (at 100% Load)6.3 Ltr/hr... Continue
Power (kVA)10 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-10EEngine MakeCummins... Continue
Power (kVA)125 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-125Phase3 PhaseFuel Consumption (at 100% Load)28.6 ltr/... Continue
Power (kVA)350 kVAGenset BrandGreaves PowerModel NumberGPWII-320Phase3 PhaseFuel C... Continue
Power (kVA)20 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-20XPhase3 PhaseFuel Consumption (at 100% Load)5 Ltr/hrFu... Continue
Power (kVA)30 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-30XPhase3 PhaseFuel Consumption (at 100% Load)7.40 Ltr/h... Continue
PhaseThree PhaseFuel Tank Capacity25 ltrPower7.5 kVAVoltage220-380 VSpeed1500 rp... Continue
Power (kVA)62.5 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-62.5Phase3 PhaseFuel Consumption (at 100% Load)14.9 lt... Continue
Power (kVA)160 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-160Phase3 PhaseFuel Consumption (at 100% Load)36.5 ltr/... Continue
PhaseThree PhaseFuel Tank Capacity122 ltrPower2750 kVASpeed1500-1800 rpmVoltage2... Continue
Power (kVA)5 kVABrandGreaves PowerModel NumberGPA II - 5PhaseSingle PhaseFuel Consumption (at 100% Load)2 ltr/hrDry Weig... Continue
Fuel Tank Capacity100 ltrPhaseThree PhasePower35 kVASpeed1500 rpmVoltage220-440 ... Continue
Power (kVA)7.5 kVAGenset BrandGreaves PowerModel NumberGPW II - 7.5Phase3 PhaseFuel Consumption (at 100% Load)2.6 ltr/hr... Continue
PhaseThree PhasePower7.5 kVAVoltage415 VApplicationIndustrialFuel TypeDieselProtectionIP 54Complete Range of Diesel/Gas ... Continue
Compression Ratio16.8Dimension3000 x 1350 x 1884 mmDisplacement4.87 LMaximum Allowable Back Pressure4.5 kPaWeight1860 kg... Continue
Genset RatingPrime PowerBrandGreaves PowerFuel TypeDieselBore & Stroke (mm)85 x 90Governor TypeMechanicalMaximum Allowab... Continue
Power (kVA)15 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-15XPhase3 PhaseFuel Consumption (at 100% Load)3.9 Ltr/hr... Continue
Power (kVA)50 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-50Phase3 PhaseFuel Consumption (at 100% Load)12.06 ltr/h... Continue
Power (kVA)75 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-75Phase3 PhaseFuel Consumption (at 100% Load)17.57 Ltr/h... Continue
Genset RatingPrime PowerBrandGreaves PowerModelG-15-IIPhaseThree PhaseOutput Volta... Continue
Power (kVA)200 kVAGenset BrandGreaves PowerPhase3 PhaseFuel Consumption (at 100% Load)23.6 ltr/hrFuel Tank Capacity350 L... Continue
Power (kVA)250 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-250Phase3 PhaseFuel Consumption (at 100% Load)58.2 Ltr/... Continue
PhaseThree PhaseBrandEicherFuel Tank Capacity100 ltrFrequency50 HzWeight3300 kg... Continue
Power (kVA)30 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-30XPhase3 PhaseFuel Consumption (at 100% Load)7.40 Ltr/h... Continue
Power (kVA)125 kVAGenset BrandGreaves PowerPhase3 PhaseFuel Consumption (at 100% Load)28.6 ltr/hrFuel Tank Capacity350 L... Continue
Power (kVA)45 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-45Phase3 PhaseFuel... Continue
Power (kVA)82.5 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-82.5Phase3 Phase... Continue